Max. number of steps per revolution: |
3,600 |
Max. number of revolutions: |
1 |
Resolution power: |
3,600 x 1 |
Error limits: |
0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) |
Repeat accuracy: |
0.005 ° |
Measuring step deviation: |
0.005 °, 0.016 ° |
Measuring step: |
360 ° /number of lines |
Initialization time: |
80 ms 1) |
Mechanical data |
Mechanical interface: |
Solid shaft, Face mount flange |
Shaft diameter: |
10 mm |
Start up torque: |
0.4 Ncm |
Operating torque: |
0.3 Ncm |
Permissible Load capacity of shaft: |
20 N (radial) 10 N (axial) |
Maximum operating speed: |
10,000 /min (without shaft seal) 6,000 /min (with shaft seal) 1) |
Moment of inertia of the rotor: |
54 gcm² |
Bearing lifetime: |
3.6 x 10^9 revolutions |
Max. angular acceleration: |
500,000 rad/s² |
Operation of zero-set: |
≥ 100 ms 2) |
Electrical data |
Operating voltage range: |
10 V DC ... 32 V DC |
Operating power consumption (no load): |
90 mA |
Interfaces |
Electrical interface: |
Cable, 22-pin, radial, 5 m |
Ambient data |
EMC: |
According to EN 61000-6-2 and EN 61000-6-3 1) |
Enclosure rating: |
IP 66, according to IEC 60529
|
Permissible relative humidity: |
90 % (condensation of the optical scanning not permitted) |
Working temperature range: |
-20 °C ... 85 °C |
Storage temperature range: |
-40 °C ... 100 °C |
Resistance to shocks: |
50 g (according to EN 60068-2-27) |
Resistance to vibration: |
20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) |