Select Store:
Select Currency:

Sick ATM90-PUF12X12 (1032661)

Product Summary

ATM90-PUF12X12 ABSOLUTE ENCODER MULTITURN 4096 x 4096, 24V / Profibus
Manufacturer: Sick
Manufacturer part number: 1032661
SKU: 112498
Weight(kg): 0.7790

Click here to check availability

Pricing - Condition Manufacturer New

€1,014.07 excl VAT
€976.55 excl VAT
Mechanical data
Mechanical interface:Through hollow shaft
Shaft diameter:10 mm 1/2 " 1)
Start up torque:0.5 Ncm (20 °C)
Operating torque:0.4 Ncm (20 °C)
Permissible movement axial static/dynamic:± 0.5 mm, ± 0.2 mm
Permissible movement radial static/dynamic:± 0.3 mm, ± 0.1 mm
Permissible shaft loading radial/axial:20 N, 10 N
Maximum operating speed:3,000 U/min
Moment of inertia of the rotor:153 gcm2
Bearing lifetime:3.6 x 10^9 revolutions
Max. angular acceleration:0,6 x 10^5 rad/s2
1) Collets for 6, 8, 10, 12 mm as accessories, separate order item. For 15 mm shaft diameter collet is not needed.  
Electrical data
Electrical interface: 10 V ... 32 V, Profibus
Connection type:Connector, 3 x M14, 7-pin, radial
Supply voltage:10 V ... 32 V
Interfaces
SET (electronic adjustment):Via PRESET push button or protocol
Bus:PROFIBUS
Bus interface:RS-485

1) 2) 3)
Data protocol:Profile for Encoders (07hex)
Encoder profile:Device Profile V0 Class 2
Address setting: 0 ... 127, DIP-switches or protocol
Data transmission rate (baud rate):9.6 kBaud 12 MBaud Automatic detection
Status information:Operation (LED green), bus aktivity (LED red)
Bus termination:via DIP-switches
Electrical connection:M14 plug connector (7 pin)
1) EN 50 170-2  2) DIN 19245 part 1-3  3) DC isolated via opto-couplers  
Ambient data
EMC:EN 61000-6-2, EN 61000-6-3
Protection class housing side with connector outlet:IP 65
Protection class shaft side:IP 65
Protection class shaft side without shaft seal:IP 43
Protection class standard:IEC 60529
Working temperature range:-20 °C ... 80 °C
Storage temperature range: -40 °C ... 125 °C, without package
Resistance to shocks:100 g, 6 ms (EN 60068-2-27)
Resistance to vibration:20, 10 ... 2,000 (EN 60068-2-6)
Air humidity:98 %
System data
Max. number of turns:4,096
Resolution:4,096 x 4,096
Error limits:± 0.25 °
Repeat accuracy:0.1
Measuring step:0.043 °
Initialization time:1,250 1)
Max. number of steps per revolution:4,096
1) Valid positional data can be read once this time has elapsed.  
Products specifications
Manufacturer category Sick ATM90P
Manufacturer Sick