Technical Data-Sender | Protective field height: | 1,800 mm |
Resolution: | 14 mm |
Housing length: | 1,923 mm |
Housing cross-section: | 48 mm x 40 mm |
Type: | Type 4 (IEC 61496) |
Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: | category 4 (EN ISO 13849) |
Performance level: | PL e (EN ISO 13849) |
PFHd: | 1.5 * 1E-08 |
TM (mission time): | 20 a |
Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC |
Response time without beam coding: | ≤ 26 ms |
Connection type: | M12 x 5, straight |
Maximum connection cable cross-section: | 0.25 mm² |
Wave length: | 950 nm |
Protection class: | III |
Enclosure rating: | IP 65 (IEC 60529) |
Ambient operating temperature: | 0 °C ... 55 °C |
Vibration resistance (checked to): | 5 g (IEC 60068-2-6) |
Oscillation frequency from ... to: | 10 Hz ... 55 Hz |
Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) |
Weight: | 3,680 g |
|
Technical Data-Receiver |
Protective field height: | 1,800 mm |
Resolution: | 14 mm |
Scanning range from ... to: | 1 m ... 5 m |
Housing length: | 1,923 mm |
Housing cross-section: | 48 mm x 40 mm |
Type: | Type 4 (IEC 61496) |
Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: | category 4 (EN ISO 13849) |
Performance level: | PL e (EN ISO 13849) |
PFHd: | 1.5 * 1E-08 |
TM (mission time): | 20 a |
Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC |
Response time without beam coding: | ≤ 26 ms |
Maximum switching current: | 500 mA |
Wave length: | 950 nm |
Connection type: | M12 x 5, straight |
Maximum connection cable cross-section: | 0.25 mm² |
Protection class: | III |
Enclosure rating: | IP 65 (IEC 60529) |
Ambient operating temperature: | 0 °C ... 55 °C |
Vibration resistance (checked to): | 5 g (IEC 60068-2-6) |
Oscillation frequency from ... to: | 10 Hz ... 55 Hz |
Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) |
Weight: | 3,710 g |
|