Beam coding: |
 |
Beam coding (delivery status): |
Non-coded |
Configuration method: |
PC with CDS (Configuration and Diagnostic Software) |
Extension connection: |
 |
Safe device communication via EFI/SDL: |
 |
Functions-Receiver |
Restart interlock: |
 |
Restart interlock (delivery status): |
External |
External device monitoring: |
 |
External device monitoring (delivery status): |
Deactivated |
Beam coding: |
 |
Beam coding (delivery status): |
Non-coded |
Bypass (with UE402): |
 |
Emergency stop / bypass at extension connection: |
- |
Operating mode switching (with UE402): |
 |
Reduced resolution: |
- |
Muting with: |
Flexi Classic |
Configuration method: |
PC with CDS (Configuration and Diagnostic Software) |
Extension connection: |
 |
Safe device communication via EFI/SDL: |
 |
Technical Data-Sender |
Protective field height: |
900 mm |
Resolution: |
14 mm |
Housing length: |
1,030 mm |
Housing cross-section: |
48 mm x 40 mm |
Type: |
Type 4 (IEC 61496) |
Safety integrity level: |
SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: |
category 4 (EN ISO 13849) |
Performance level: |
PL e (EN ISO 13849) |
PFHd: |
1.5 * 1E-08 |
TM (Mission Time): |
20 a |
Enclosure rating: |
IP 65 |
Protection class: |
III |
Ambient operating temperature from ... to: |
0 °C ... 55 °C |
Vibration resistance (checked to): |
5 g (IEC 60068-2-6) |
Oscillation frequency from ... to: |
10 Hz ... 55 Hz |
Shock resistance: |
10 g, 16 ms (IEC 60068-2-29) |
Supply voltage typical, from, to: |
24 V DC, 19.2 V DC, 28.8 V DC |
Power consumption: |
≤ 2 A |
Wave length: |
950 nm |
Connection type: |
Hirschmann plug M26 x 11 + FE |
Connection type configuration connection: |
M8 x 4 |
Connection type extension connection: |
M12 x 7 + FE |
Maximum connection cable cross-section: |
0.75 mm2 |
Technical Data-Receiver |
Protective field height: |
900 mm |
Resolution: |
14 mm |
Scanning range from ... to: |
0 m ... 8 m |
Scanning range from ... to (delivery status): |
0 m ... 2.5 m |
Housing length: |
1,030 mm |
Housing cross-section: |
48 mm x 40 mm |
Type: |
Type 4 (IEC 61496) |
Safety integrity level: |
SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: |
category 4 (EN ISO 13849) |
Performance level: |
PL e (EN ISO 13849) |
PFHd: |
1.5 * 1E-08 |
TM (Mission Time): |
20 a |
Enclosure rating: |
IP 65 |
Protection class: |
III |
Ambient operating temperature from ... to: |
0 °C ... 55 °C |
Vibration resistance (checked to): |
5 g (IEC 60068-2-6) |
Oscillation frequency from ... to: |
10 Hz ... 55 Hz |
Shock resistance: |
10 g, 16 ms (IEC 60068-2-29) |
Response time without beam coding: |
≤ 17 ms |
Response time with beam coding: |
≤ 33 ms |
Supply voltage typical, from, to: |
24 V DC, 19.2 V DC, 28.8 V DC |
Power consumption: |
≤ 3 A |
Maximum switching current: |
500 mA |
Wave length: |
950 nm |
Connection type: |
Hirschmann plug M26 x 11 + FE |
Connection type configuration connection: |
M8 x 4 |
Connection type extension connection: |
M12 x 7 + FE |
Maximum connection cable cross-section: |
0.75 mm2 |