Beam coding: |
- |
Reduced resolution: |
- |
Configuration method: |
hard wired |
Extension connection: |
- |
Safe device communication via EFI/SDL: |
- |
Functions-Receiver |
Restart interlock: |
 |
Restart interlock (delivery status): |
Internal |
External device monitoring: |
 |
External device monitoring (delivery status): |
Deactivated |
Beam coding: |
- |
PSDI mode with: |
Flexi Soft |
Reduced resolution: |
- |
Muting with: |
Flexi Classic |
Configuration method: |
hard wired |
Extension connection: |
- |
Safe device communication via EFI/SDL: |
- |
Technical Data-Sender |
Protective field height: |
1,200 mm |
Resolution: |
30 mm |
Housing length: |
1,296 mm |
Housing cross-section: |
33.5 mm x 28.5 mm |
Type: |
Type 4 (IEC 61496) |
Safety integrity level: |
SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: |
category 4 (EN ISO 13849) |
Performance level: |
PL e (EN ISO 13849) |
PFHd: |
1.5 * 1E-08 |
TM (Mission Time): |
20 a |
Enclosure rating: |
IP 65 |
Protection class: |
III (IEC 536:1976) |
Ambient operating temperature from ... to: |
-30 °C ... 55 °C |
Vibration resistance (checked to): |
5 g (IEC 60068-2-6) |
Oscillation frequency from ... to: |
10 Hz ... 55 Hz |
Shock resistance: |
10 g, 16 ms (IEC 60068-2-29) |
Weight: |
1,235 g |
Supply voltage typical, from, to: |
24 V DC, 19.2 V DC, 28.8 V DC |
Wave length: |
950 nm |
Connection type: |
M12 x 7 + FE, straight |
Maximum connection cable cross-section: |
0.25 mm2 |
Technical Data-Receiver |
Protective field height: |
1,200 mm |
Resolution: |
30 mm |
Scanning range from ... to: |
0 m ... 6 m |
Housing length: |
1,296 mm |
Housing cross-section: |
33.5 mm x 28.5 mm |
Type: |
Type 4 (IEC 61496) |
Safety integrity level: |
SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: |
category 4 (EN ISO 13849) |
Performance level: |
PL e (EN ISO 13849) |
PFHd: |
1.5 * 1E-08 |
TM (Mission Time): |
20 a |
Enclosure rating: |
IP 65 |
Protection class: |
III (IEC 536:1976) |
Ambient operating temperature from ... to: |
-30 °C ... 55 °C |
Vibration resistance (checked to): |
5 g (IEC 60068-2-6) |
Oscillation frequency from ... to: |
10 Hz ... 55 Hz |
Shock resistance: |
10 g, 16 ms (IEC 60068-2-29) |
Weight: |
1,250 g |
Response time without beam coding: |
≤ 13 ms |
Supply voltage typical, from, to: |
24 V DC, 19.2 V DC, 28.8 V DC |
Maximum switching current: |
500 mA |
Wave length: |
950 nm |
Connection type: |
M12 x 7 + FE, straight |
Maximum connection cable cross-section: |
0.25 mm2 |