Functions-Sender | Beam coding: |  |
Beam coding (delivery status): | Non-coded |
Configuration method: | PC with CDS (Configuration and Diagnostic Software) |
Extension connection: | - |
Safe device communication via EFI/SDL: | - |
|
Functions-Receiver |
Restart interlock: | - |
External device monitoring: | - |
Beam coding: |  |
Beam coding (delivery status): | Non-coded |
Bypass (with UE402): | - |
Emergency stop / bypass at extension connection: | - |
Operating mode switching (with UE402): | - |
Reduced resolution: |  |
Muting with: | Flexi Classic |
Configuration method: | PC with CDS (Configuration and Diagnostic Software) |
Extension connection: | - |
Safe device communication via EFI/SDL: | - |
|
Technical Data-Sender |
Protective field height: | 1,350 mm |
Resolution: | 14 mm |
Housing length: | 1,430 mm |
Housing cross-section: | 48 mm x 40 mm |
Type: | Type 4 (IEC 61496) |
Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: | category 4 (EN ISO 13849) |
Performance level: | PL e (EN ISO 13849) |
PFHd: | 1.5 * 1E-08 |
TM (Mission Time): | 20 a |
Enclosure rating: | IP 65 |
Protection class: | III |
Ambient operating temperature from ... to: | 0 °C ... 55 °C |
Vibration resistance (checked to): | 5 g (IEC 60068-2-6) |
Oscillation frequency from ... to: | 10 Hz ... 55 Hz |
Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) |
Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC |
Power consumption: | ≤ 2 A |
Wave length: | 950 nm |
Connection type: | fixed connection cable 320 mm with plug M12 x 7 + FE, straight |
Maximum connection cable cross-section: | 0.25 mm2 |
|
Technical Data-Receiver |
Protective field height: | 1,350 mm |
Resolution: | 14 mm |
Scanning range from ... to: | 0 m ... 8 m |
Scanning range from ... to (delivery status): | 0 m ... 2.5 m |
Housing length: | 1,430 mm |
Housing cross-section: | 48 mm x 40 mm |
Type: | Type 4 (IEC 61496) |
Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: | category 4 (EN ISO 13849) |
Performance level: | PL e (EN ISO 13849) |
PFHd: | 1.5 * 1E-08 |
TM (Mission Time): | 20 a |
Enclosure rating: | IP 65 |
Protection class: | III |
Ambient operating temperature from ... to: | 0 °C ... 55 °C |
Vibration resistance (checked to): | 5 g (IEC 60068-2-6) |
Oscillation frequency from ... to: | 10 Hz ... 55 Hz |
Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) |
Response time without beam coding: | ≤ 22 ms |
Response time with beam coding: | ≤ 44 ms |
Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC |
Power consumption: | ≤ 3 A |
Maximum switching current: | 500 mA |
Wave length: | 950 nm |
Connection type: | fixed connection cable 320 mm with plug M12 x 7 + FE, straight |
Maximum connection cable cross-section: | 0.25 mm2 |
|