Select Store:
Select Currency:

Sick DFS60E-T4EL02048 (1036219)

Product Summary

DFS60E-T4EL02048 INCREMENTAL ENCODER 02048 Lines, 10...32V, HTL / push pull
Manufacturer: Sick
Manufacturer part number: 1036219
SKU: 115115
Weight(kg): 0.3350

Click here to check availability

Pricing - Condition Manufacturer New

€242.86 excl VAT
€233.87 excl VAT
Mechanical data
Shaft diameter:10 mm
Moment of inertia of the rotor:40 gcm2
Max. angular acceleration:5 x 10^5 rad/s2
Start up torque:0.8 Ncm (20 °C)
Operating torque:0.6 Ncm (20 °C)
Mechanical interface:Through hollow shaft, plastic
Mass:0.2 kg (For an encoder with connector outlet)
Bearing lifetime:3 x 10^9 revolutions
Permissible movement axial static/dynamic:± 0.5 mm, ± 0.2 mm
Permissible movement radial static/dynamic:± 0.3 mm, ± 0.1 mm
Maximum operating speed:9,000 U/min 1)
1) Self-warming 3.3k per 1,000 1/min  
Electrical data
Connection type:Cable, universal, 3 m
Reference signal, number:1
Reference signal, position:90 °, electronically, gated with A and B
Electrical interface: 10 V ... 32 V, HTL/push pull
Operating power consumption (no load):40 mA
Supply voltage:10 V ... 32 V
Load current:30
Maximum output frequency:300 kHz
Ambient data
Resistance to shocks:50 g, 6 ms (EN 60068-2-27)
Resistance to vibration:20, 10 ... 2,000 (EN 60068-2-6)
EMC:EN 61000-6-2, EN 61000-6-4
Protection class housing side with connector outlet:IP 65 1)
Protection class housing side with cable outlet:IP 65
Protection class shaft side:IP 65
Protection class standard:IEC 60529
Air humidity:90 % 2)
Working temperature range:0 °C ... 70 °C
Storage temperature range: -40 °C ... 100 °C, without package
1) With mating connector fitted  2) Condensation of the optical scanning not permitted  
System data
Measuring step:90 °, electronically/number of lines
Measuring step deviation:± 0.2 °
Number of lines per revolution:2,048
Error limits:± 0.3 °
Initialization time:40
Products specifications
Manufacturer category Sick DF60TN
Manufacturer Sick