Technical data | Type of command unit: | Emergency stop pushbutton |
Mounting version: | Panel mount version |
Protection class: | II (EN 50178) |
Ambient operating temperature: | -30 °C ... 85 °C |
B10d parameter: | 4.75* 1E 06 switching cycles |
Switching principle: | Slow action switching element |
Number of positive action N/C contacts: | 2 |
Number of N/O contacts: | 1 |
Mechanical life (relay contacts): | 1* 1E 06 switching cycles |
Electrical life: | 1* 1E 06 switching cycles 1) |
Usage category: | AC-15/DC-13 (EN 60947-5-1) |
Rated operating current (voltage): | 3 A (250 V AC) 2 A (24 V DC) |
Rated current (voltage) according to EN 61058-1: | 16 A (10 A) 250 V AC 10 A (6 A) 440 V AC |
Emergency stop button (illuminable): |  |
Operating voltage (illumination) typ., from, to: | 24 V DC, 12 V DC, 30 V DC |
Operating current (illumination): | 8 mA ... 44 mA |
Contact module for panel mount version: |  |
Weight: | 95 g |
|