Select Store:
Select Currency:

Sick KHK53-PXF00354 (1036165)

Product Summary

KHK53-PXF00354 Absol. Linear Encoder Read Head 354, 24 V / Profibus, with Link Adaptor
Manufacturer: Sick
Manufacturer part number: 1036165
SKU: 115065
Weight(kg): 4.9310

Click here to check availability

Pricing - Condition Manufacturer New

€3,800.38 excl VAT
€3,659.77 excl VAT

Downloads

  • Non-contact length measurement - maintenance-free, rugged, long lifetime
  • High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm)
  • SSI and PROFIBUS interfaces
  • Determination of absolute position
  • Measuring lengths of up to 1,700 m possible
  • Can be used in harsh environments
  • High travel speeds of up to 6.6 m/s
  • Distance tolerance between read head and measuring element: up to 55 mm ± 20 mm possible
  • Your benefits

  • After installation, the system is immediately available and completely maintenance-free, which leads to time and cost savings.
  • Reliable determination of position under harshest environmental conditions such as influences of dirt, dust, fog, shocks and vibrations
  • High efficiency and productivity
  • Savings on time - no reference run necessary on initial operation due to absolute position measurement
  • accurate positioning even with high mounting tolerances

Performance
Measuring length:0 m ... 354 m
Measuring range:354 m
Resolution:0.1 mm
Piston speed:6.6 m/s 1)
Measurement accuracy:± 1000 + ME (Tu-25° C) Tk µm 2)
Repeat accuracy:0.3 mm
1) If the max. movement speed is exceeded or the read head cannot detect a measuring element an error message is produced.  2) If the read head and measuring element are mounted within ± 1 mm of the nominal mounting distance in the N and Y directions. The figures quoted related to the accuracy within a measuring element with reference to the start of that measuring element. ME = length measuring element Tu = Ambient temperature °C  
Mechanical data
Connection type:3 x connector M12
Mass:3.6 kg
Position tolerance:± 10 mm
Material:AlMgSiPbF28
Electrical data
Initialization time:2 s
Position forming time:1.1 ms
Supply voltage:10 V ... 32 V
Power consumption:2.5 W
MTTFd: mean time to dangerous failure:28 a (EN ISO 13849) 1)
1) This product is a standard product and does not constitute a
safety component as defined in the Machinery Directive.
Calculation based on nominal load of components, average ambient
temperature 40°C, frequency of use 8760 h/a. All
electronic failures are considered hazardous. For more information, see document no. 8015532.  
Interfaces
Electrical interface:PROFIBUS DP
Bus interface:RS-485 1) 2) 3)
SET (electronic adjustment):Via protocol
Address setting:0 ... 127, Hex switches or Protocol
Data protocol:Profibus DP basic functions, Profile for encoders (07hex) - Class 2
Status information:Operation (LED green), Bus aktivity (LED red)
Bus termination:Via external switches
1) EN 50 170-2  2) DIN 19245 part 1-3  3) DC isolated via opto-couplers  
Ambient data
EMC:(according to EN 61000-6-2 and EN 61000-6-4) 1)
Enclosure rating:IP 67 (IEC 60529), with mating connector inserted
Working temperature range:-20 °C ... 60 °C
Storage temperature range:-40 °C ... 85 °C
Resistance to shocks:30 g, 10 ms (DIN EN 61000-2-27)
Resistance to vibration:10 g, 20 Hz ... 250 Hz (DIN EN 61000-2-6)
1)   
Products specifications
Manufacturer category Sick KHK53
Manufacturer Sick