Product Summary

MAGN.POSITIONSSENSOR
Manufacturer: Sick
Manufacturer part number: 1050922
SKU: 187505
Click here to check availability

Pricing - Condition Manufacturer New

€261.25 excl VAT
€248.18 excl VAT

Downloads

  • Magnetic position sensor for pneumatic and hydraulic cylinders with T-slot
  • Output signal: analog, 4 - 20 mA current and 0 -10 V (in one sensor)
  • Superior? precision: 0.05 mm resolution, 0.1 mm repeatability, 0.3 mm linearity, 1 ms ?measurement?rate
  • Various lengths available from 32 - 256 mm
  • Your benefits

  • Maximum flexibility with several different measuring ranges from 32 to 256 mm
  • Drop-in T-slot mounting from above makes assembly easy
  • Selectable?installation?direction?to optimize cabeling
  • Efficient?measurement?of?stroke due?to?minimal?blind?zones, increasing machine throughput
  • Simple commissioning due to "in-range" indicator
  • Output signal: analog, 4 - 20 mA current and 0 -10 V (in one sensor) reduces inventory cost by part number reduction

Features
Output function:Analog
Electrical wiring:DC 4-wire
Teach-in:0
Cylinder type:T-slot
Cylinder types with adapter:Roundbody cylinder
SMC rail cylinder CDQ2
SMC rail cylinder ECDQ2
Cylinders with dovetail slots
Measuring range:160 mm 1)
Housing length:173 mm
Analog output (voltage):0 V ... 10 V
Analog output (current):4 mA ... 20 mA
Enclosure rating:IP 67 2)
1) ± 1 mm  2) According to EN 60529  
Mechanics/electronics
Connection type:Cable, 2 m 1)
Supply voltage:15 V DC ... 30 V DC
EMC:According to EN 60947-5-2 2)
Load resistance, max.:500 Ω 3)
Min. load resistance:2 kΩ 4)
Cable material:PUR
Conductor cross-section:0.14 mm²
Reverse polarity protection:
Short-circuit protection:
Housing material:Plastic
Output indicator:
Linearity typ.:0.3 mm
Resolution typ.:0.03 % FSR (max. >= 0.05 mm) 5)
Repeat accuracy typ:0.06 % FSR (>= 0.1 mm) 6)
Shock/vibration:30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature:-20 °C ... 70 °C
Protection class:III
Magnetic field sensitivity, typ.:3 mT
Sampling rate typ.:1 ms
1) Do not bend below 0 °C  2) The analog measured value can deviate under transient conditions  3) Power output  4) Voltage output  5) 6) FSR: Full Scale Range; max. measuring range  
Products specifications
Manufacturer category Sick MPS
Manufacturer Sick