Select Store:
Select Currency:

Sick MPS-160TSTU0 (1050740)

Product Summary

MAGN.POSITIONSSENSOR
Manufacturer: Sick
Manufacturer part number: 1050740
SKU: 187880
Click here to check availability

Pricing - Condition Manufacturer New

€264.95 excl VAT
€251.70 excl VAT

Downloads

  • Analog positioning sensor for pneumatic and hydraulic cylinders with T-slot
  • Measuring lengths from 32 mm to 256 mm in 32 mm steps
  • Output signals 4 mA to 20 mA as well as 0 V to 10 V in a single sensor
  • Superior precision: 0.05 mm resolution typ., 0.1 mm repeatability typ., 0.3 mm linearity typ., 1 ms measurement rate typ.
  • Electric setting of zero point and end point via teach-in button (optional)
  • Your benefits

  • Convenient installation and sensor replacement due to drop-in installation
  • Maximum flexibility through measuring ranges from 32 mm to 256 mm
  • Increased machine performance thanks to the sensor’s minimal blind zone
  • Easy analog output setup: adjustable zero and end point can be taught via single button
  • Selectable installation direction to optimize cabling
  • Simple commissioning due to “in-range” indicator
  • Flexible sensor settings, monitoring, advanced diagnostics, and visualization thanks to IO-Link save time and money

Features
Output function:Analog
Electrical wiring:DC 4-wire
Teach-in:1
Cylinder type:T-slot
Cylinder types with adapter:Roundbody cylinder
SMC rail cylinder CDQ2
SMC rail cylinder ECDQ2
Cylinders with dovetail slots
Measuring range:160 mm 1)
Housing length:173 mm
Analog output (voltage):0 V ... 10 V
Analog output (current):4 mA ... 20 mA
Enclosure rating:IP 67 2)
1) ± 1 mm  2) According to EN 60529  
Mechanics/electronics
Connection type:Cable, 2 m 1)
Supply voltage:15 V DC ... 30 V DC
EMC:According to EN 60947-5-2 2)
Load resistance, max.:500 Ω 3)
Min. load resistance:2 kΩ 4)
Cable material:PUR
Conductor cross-section:0.14 mm²
Reverse polarity protection:
Short-circuit protection:
Housing material:Plastic
Output indicator:
Linearity typ.:0.3 mm
Resolution typ.:0.03 % FSR (max. >= 0.05 mm) 5)
Repeat accuracy typ:0.06 % FSR (>= 0.1 mm) 6)
Shock/vibration:30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature:-20 °C ... 70 °C
Protection class:III
Magnetic field sensitivity, typ.:3 mT
Sampling rate typ.:1 ms
1) Do not bend below 0 °C  2) The analog measured value can deviate under transient conditions  3) Power output  4) Voltage output  5) 6) FSR: Full Scale Range; max. measuring range  
Products specifications
Manufacturer category Sick MPS
Manufacturer Sick