Features | Output type: | NAMUR |
Electrical wiring: | DC 2-wire |
Sensing face: | Front |
Cylinder types with adapter: | Roundbody cylinder |
Switching frequency: | 5,000 Hz |
Enclosure rating: | IP 67 1) |
|
Mechanics/electronics |
Connection type: | Cable, 2-wire, 2 m |
Supply voltage: | 5 V DC ... 25 V DC |
Voltage drop: | ≤ 1.5 V 1) |
Output current Ia: | ≤ 300 mA |
Temperature drift (of Sr): | ± 0.005 mm/°C |
EMC: | According to EN 60947-5-6 |
Current consumption, sensor is activated: | ≥ 2.5 mA |
Current consumption, sensor is not activated: | ≤ 1 mA |
Cable material: | PVC |
Conductor cross-section: | 0.34 mm² |
Cable resistance: | ≤ 50 Ω |
Short-circuit protection: |  |
Housing material: | Metal, Aluminum |
Sensing face material: | Plastic |
EC Approval Certificate: | TÜV 99 ATEX 1398 |
ATEX marking: | EX II 2 G Ex ia IIC T6 Ta: -20...70°C |
Input voltage Ui max.: | 16 V |
Input power Pi max.: | 100 mW |
Input current Ii max.: | 30 mA |
Internal capacitance Ci max.: | 15 nF |
Internal inductance Li max.: | ≤ 35 µH |
Nominal voltage: | 8.2 V DC |
Time delay before availability: | ≤ 2 ms |
Magnetic field sensitivity, min.: | ≤ 3 mT |
Repeatability: | ≤ 0.1 mm 2) |
Ambient operating temperature: | -25 °C ... 70 °C |
Housing length: | 30 mm |
Shock/vibration: | 30 g, 11 ms/10 ... 55 Hz, 1 mm |
|