Product Summary

MZT6-03VPS-KWX Magnetic cylinder sensor, DC 3-wire, PNP, NO, cable 2m, PVC EX 3G EEx nA II T4X EX 3D T100 Grad IP67 >> We would like to point out relating to the Directive 94/9/EC (ATEX) and EN13980 that you are responsible for the traceability of the ord
Manufacturer: Sick
Manufacturer part number: 1025827
SKU: 182149
Weight(kg): 0.0333

Click here to check availability

Pricing - Condition Manufacturer New

€50.54 excl VAT
€48.01 excl VAT

Downloads

  • ATEX 3D / 3G and ATEX 3G
  • Compact housing design
  • Combined Allen and flathead installation screw
  • LED function indicator
  • For all commonly used cylinders with T-slots, e.g., Festo or SMC and it can be applied to multiple cylinders types such as round, tie-rod, integrated profile or dove-tail cylinders with mounting brackets
  • Your benefits

  • High switching performance for machine environments in explosion areas
  • Highly resistant to shock and vibration enlarging sensor life time
  • Convenient installation and sensor replacement due to drop-in installation - installer does not need to disassemble the cylinder from the machine for sensor replacement.
  • Flexible installation via Allen wrench or flathead screwdriver
  • Leakproof design with high resistance to liquids increases application reliability

Features
Switching frequency typ.:± 1,000 Hz
Switching output:PNP
Output function:NO
Electrical wiring:DC 3-wire
Cylinder type:T-slot
Cylinder types with adapter:Profile cylinder
Roundbody cylinder
SMC rail cylinder CDQ2
SMC rail cylinder ECDQ2
Tie rod cylinder
Cylinders with dovetail slots
Housing length:31.5 mm
Enclosure rating:IP 67
1)
1) According to EN 60529  
Mechanics/electronics
Connection type:Cable, 3-wire, 2 m
Supply voltage:18 V DC ... 30 V DC
Power consumption:≤ 10 mA 1)
Voltage drop:≤ 2.2 V
Output current Ia:≤ 70 mA
EMC:According to EN 60947-5-2
Cable material:PVC
Conductor cross-section:0.14 mm²
Reverse polarity protection:
Short-circuit protection:
Housing material:Plastic
ATEX marking:Ex II 3D T100 °C IP 67, Ex II 3G EEx nA II T4 X
Power-up pulse protection:
Repeatability:≤ 0.1 mT 2)
Overrun distance typ.:3 mm
Shock/vibration:30 g, 11 ms / 10 ... 55 Hz, 1 mm
Ambient operating temperature:-20 °C ... +45 °C
Hazardous area category:3D, 3G
Protection class:III
Hysteresis typ.:≤ 0.5 mT
Magnetic field sensitivity, typ.:2.6 mT
1) Without load  2) Ub and Ta constant  