Sick PFT-SAB2X5SG1SSAAMSSZ (6038766)

Product Summary

PFT Pressure Transmitter 0...2.5 bar abs Accuracy +/- 0.5% of Span (BFSL) G 1/4 A according to DIN 3852-E Standard pressure port -30... +100degC - 4...20 mA, 2-wire M12 x 1, 4-pin Supply Voltage 10...30 VDC without certificates
Manufacturer: Sick
Manufacturer part number: 6038766
SKU: 182416
Weight(kg): 0.9990

Click here to check availability

Pricing - Condition Manufacturer New

€368.25 excl VAT
€349.83 excl VAT
    • Absolute pressure measurement ranges from 0 ... 0.25 bar up to 0 … 25 bar
    • Process temperature up to 125 °C (optional)
    • High shock and vibration resistance
    • Accuracy 0.5% or 0.25%
    • Output signal 4 … 20 mA, 0 … 5 V, or 0 … 10 V
    • Zero and span adjustable
    • Electrical connection M12x1, L-connector according to DIN 175301-803 A or flying leads

Your benefits

  • Reliable and highly accurate measurement technology
  • Wide application range
  • No mechanical wear, fatigue-proof, maintenance-free as no moving parts
  • Simple and cost-saving installation
  • Optimal solution for individual requirements due to very versatile configurability
  • Maximum installation flexibility due to availability of a large range of customary thread types

 

Features

Pressure type: Absolute Pressure
Measuring range: 0 bar ... 2.5 bar
Process temperature: -30 °C ... 100 °C
Rated temperature: 0 °C ... 80 °C
CE-conformity:
Output signal: 4...20 mA
 
Performance
Accuracy: <= +/- 0.5 % (of span)
Non-linearity: ± 0.2 % (Best Fit Straight Line (BFSL))
Response time: <= 1 ms (≤ 10 ms at medium temperatures below < -30°C for pressure ranges up to 25 bar or with flush-mounted membrane)
 
Mechanics/electronics
Process connection: G 1/4 A (DIN 3852-E)
Wetted parts: Standard: Stainless steel
Seal: Without seal
Pressure port: Standard
Housing material: Stainless steel
Enclosure rating: IP 67
Connection type: M12x1, 4-pin
Supply voltage: 10 V DC ... 30 V DC
Electrical safety: Short-circuit protection: QA towards M, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M
Dielectric strength: 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions)
Protection class III:
 
Ambient data
Ambient temperature: -20 °C ... 80 °C
Shock load: 1000 g according to IEC 60068-2-27 (mechanical shock)
Vibration load: 20 g according to IEC 60068-2-6 (vibration under resonance)
 
Products specifications
Manufacturer category Sick PFT