Features | Pressure type: | Gauge pressure |
Measuring range: | 0 bar ... 0.6 bar |
Process temperature: | -40 °C ... 125 °C |
CE-conformity: | |
Output signal: | 4...20 mA |
|
Performance |
Accuracy: | <= +/- 0.5 % (of span) |
Non-linearity: | <= +/- 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) |
Long-term drift/one-year stability: | <= +/- 0.2 % of span (at reference conditions) |
Temperature coefficient in rated temperature range: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.2 % of span / 10 K (< 0.4 % for pressure ranges ≤ 0.25 bar) |
Rated temperature range: | 0 °C ... 80 °C |
Non-repeatability: | <= +/- 0.1 % of span |
Response time (10 % ... 90 %): | ≤ 1 ms (≤ 10 ms at medium temperatures below < -30°C for pressure ranges up to 25 bar or with flush-mounted membrane) |
|
Mechanics/electronics |
Process connection: | G 1/2 B according to EN 837 |
Wetted parts: | Standard: Stainless steel |
Seal: | Without seal |
Pressure port: | Standard |
Housing material: | Stainless steel |
Enclosure rating: | IP 67 |
Connection type: | M12 x 1, 4-pin, IP 67 |
Supply voltage: | 10 V DC ... 30 V DC |
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M |
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) |
Protection class III: | |
Weight sensor: | 200 g |
CE-conformity: | Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EEC, EN 61326-2-3 |
|
Ambient data |
Storage temperature: | -40 °C ... 100 °C |
Ambient temperature: | -20 °C ... 80 °C |
Shock load: | 1000 g according to IEC 60068-2-27 (mechanical shock) |
Vibration load: | 20 g according to IEC 60068-2-6 (vibration under resonance) |
|