Applications | Type of switching amplifier: | Contact expansion module |
Emergency stop pushbuttons: | - |
Safety switches: | - |
Safety Switch with mechanical lock: | - |
Two-hand control systems: | - |
Pressure sensitive mats: | - |
Opto-electronic protective devices: | - |
Opto-electronic protective devices without RES/EDM: | - |
Opto-electronic protective devices with RES/EDM: | - |
System part: | Safety relays |
|
Functions |
Cross-circuit detection: | - |
Reset/restart: | Automatic |
External device monitoring: | - |
|
Technical data |
Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) 1) |
Category: | Category 4 (EN ISO 13849) 2) |
Performance level: | PL d (EN ISO 13849) 3) |
B10d parameter: | 1* 1E 06 switching cycles (AC-15, 230 V, I = 0.5 A) 3*1E 05 switching cycles (DC-13, 24 V, I = 2 A) 1.2 * 1E 06 switching cycles (DC-13, 24 V, I = 0.5 A) |
PFHd: | 2.0 * 1E-07 |
TM (mission time): | 4 a |
Width: | 22.5 mm |
Contact type: | Positively driven |
Number of enable current contacts: | 4 |
Number of delayed deactivation signalling current contacts: | 2 |
Delay time: | 2 s |
Operating voltage DC: | 24 V DC |
Maximum power consumption DC: | 2 W |
Type of output: | Relay contacts |
Rated operating current (voltage): | 6 A (230 V AC) 3600 switching cycles/h 6 A (24 V DC) 360 switching cycles/h 3 A (24 V DC) 3600 switching cycles/h |
Maximum switching current: | 6 A |
Maximum total current: | 12 A |
Mechanical life (relay contacts): | 1*1E 07 switching cycles |
Electrical life (relay contacts): | 2* 1E 06 switching cycles, dependent upon loading, details see operating instructions |
Enclosure rating: | IP 20 |
Ambient operating temperature from ... to: | -25 °C ... 55 °C |
Connection type: | Screw-type terminals |
|