Applications | Type of switching amplifier: | Main unit |
Emergency stop pushbuttons: | |
Safety switches: | |
Safety Switch with mechanical lock: | - |
Two-hand control systems: | - |
Pressure sensitive mats: | - |
Opto-electronic protective devices: | - |
Opto-electronic protective devices without RES/EDM: | - |
Opto-electronic protective devices with RES/EDM: | - |
System part: | Safety relays |
|
Functions |
Input circuit: | Single- or dual-channel |
Cross-circuit detection: | |
Reset/restart: | Manual / automatic / configurable |
External device monitoring: | |
Synchronous time monitoring: | |
|
Technical data |
Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: | Category 4 (EN ISO 13849) |
Performance level: | PL e (EN ISO 13849) |
B10d parameter: | 1* 1E 06 switching cycles (AC-15, 230 V, I = 0.5 A) 3.5*1E 05 switching cycles (DC-13, 24 V, I = 2 A) 1.2 * 1E 06 switching cycles (DC-13, 24 V, I = 0.5 A) |
PFHd: | 3.0 * 1E-08 |
TM (mission time): | 20 a |
Stop category: | 0, EN 60204 |
Width: | 45 mm |
Contact type: | Positively driven |
Number of enable current contacts: | 3 |
Number of signalling current contacts: | 1 |
Operating voltage AC: | 120 V AC |
Maximum power consumption AC: | 3.2 VA |
Maximum power consumption DC: | 2.5 W |
Type of output: | Relay contacts |
Rated operating current (voltage): | 6 A (230 V AC) 3600 switching cycles/h 6 A (24 V DC) 360 switching cycles/h 3 A (24 V DC) 3600 switching cycles/h |
Maximum switching current: | 6 A |
Maximum total current: | 18 A |
Mechanical life (relay contacts): | 1*1E 07 switching cycles |
Electrical life (relay contacts): | 2* 1E 06 switching cycles, dependent upon loading, details see operating instructions |
Enclosure rating: | IP 20 |
Ambient operating temperature from ... to: | -25 °C ... 55 °C |
Connection type: | Screw-type terminals |
|