Type of switching amplifier: |
Main unit |
Emergency stop pushbuttons: |
|
Safety switches: |
|
Safety Switch with mechanical lock: |
- |
Two-hand control systems: |
- |
Pressure sensitive mats: |
- |
Opto-electronic protective devices: |
- |
Opto-electronic protective devices without RES/EDM: |
- |
Opto-electronic protective devices with RES/EDM: |
- |
System part: |
Safety relays |
Functions |
Input circuit: |
Single- or dual-channel |
Cross-circuit detection: |
|
Reset/restart: |
Manual / automatic / configurable |
External device monitoring: |
|
Synchronous time monitoring: |
|
Technical data |
Safety integrity level: |
SILCL3 (IEC 62061) SILCL2 (IEC 62061) 1) 2) |
Category: |
Category 4 (EN ISO 13849) category 3 (EN ISO 13849) 3) 4) |
Performance level: |
PL e (EN ISO 13849) PL d (EN ISO 13849) 5) 6) |
B10d parameter: |
4*1E 05 switching cycles (with maximum load) |
PFHd: |
3.0 * 1E-08 2.0 * 1E-08 |
TM (mission time): |
20 a |
Stop category: |
1, 0, EN 60204 |
Width: |
22.5 mm |
Contact type: |
Positively driven |
Number of enable current contacts: |
2 |
Number of off-delayed N/O contacts: |
1 |
Number of signalling current contacts: |
0 |
Delay time: |
0.15 s ... 3 s |
Operating voltage DC: |
24 V DC |
Maximum power consumption DC: |
2.6 W |
Type of output: |
Relay contacts |
Rated operating current (voltage): |
4 A (230 V AC) 3600 switching cycles/h 5 A (24 V DC) 360 switching cycles/h 3 A (24 V DC) 3600 switching cycles/h |
Maximum switching current: |
6 A |
Maximum total current: |
12 A |
Mechanical life (relay contacts): |
5*1E 06 switching cycles |
Electrical life (relay contacts): |
2* 1E 06 switching cycles, dependent upon loading, details see operating instructions |
Enclosure rating: |
IP 20 |
Ambient operating temperature from ... to: |
-25 °C ... 55 °C |
Connection type: |
Plug-in terminals |