Resolution: |
≤ 0.18 mm |
Working range, limiting range: |
350 mm ... 3,400 mm, 5,000 mm |
Repeatability 1): |
± 0.15 % |
Accuracy 2) 3): |
± 1 % |
Response time: |
180 ms |
Output rate: |
43 ms |
Ultrasonic frequency (typical): |
120 kHz |
Detection area (typical): |
See diagrams |
Temperature compensation: |
 |
Additional function: |
Teach-in of analog output Automatic selection of analog current or voltage output Temperature compensation Synchronization of up to 10 sensors Multiplexing: no cross talk of up to 10 sensors Set measurement filters: value filter, filter strength, adjustable sensitivity, foreground suppression and detection area Reset to factory default Switch-off display Scaling of analog outputs Invertible analog output |
Interfaces |
Analog output 1) 2) 3) 4): |
1 x 0 V ... 10 V (≥ 100 kΩ), 1 x 4 mA ... 20 mA (≤ 500 Ω) |
Resolution analog output: |
12 bit |
Multifunctional input (MF): |
1 x MF |
BETRIEBSREICHWEITE-GR.COLL: |
350 mm 3,400 mm 5,000 mm |
Mechanics/electronics |
Sending axis: |
Straight |
Supply voltage Vs 1) 2): |
DC 9 V ... 30 V |
Power consumption 3): |
≤ 2.4 W |
Initialization time: |
< 300 ms |
Housing material: |
Nickel-plated brass, PBT display: TPU ultrasonic transducer: polyurethane foam, glass epoxy resin |
Connection type: |
Male connector, M12, 5-pin |
Indication: |
LED display, 2 x LED |
Weight: |
210 g |
Ambient data |
Enclosure rating: |
IP 67 |
Protection class: |
III |
Ambient temperature: |
Operation: -25 ... +70 °C Storage: -40 ... +85 °C |