Select Store:
Select Currency:

Sick UP56-213118 (6041660)

Product Summary

ULTRASONIC SENSOR
Manufacturer: Sick
Manufacturer part number: 6041660
SKU: 185886
Weight(kg): 0.2410

Click here to check availability

Pricing - Condition Manufacturer New

€721.65 excl VAT
€692.59 excl VAT
    • Non-contact level measurement up to 3.4 m operating distance / 8.0 m limit scanning distance
    • Pressure resistant up to 6 bar (87 psi)
    • Transducer protected by PVDF cover for increased resistance
    • 3 in 1: continuous level measurement, level switch and display
    • Analog output switchable between 4 mA ... 20 mA and 0 V … 10 V
    • Process connector thread G 1 and G 2
    • IP 67 enclosure rating
    • Easy to set parameters, also via connect+

Your benefits

  • Non-contact measurement in pressurized containers - no wear over time
  • Easy to set parameters, saving time
  • Flexible measurement system for different container sizes - standardization and stock reduction
  • One product for point level and continuous applications, reduces the number of sensors required

 

Features

Medium: Fluids
Measurement: Switch, Continuous
Limiting scanning distance: 200 mm ... 5,000 mm 1)
Operating distance: 200 mm ... 1,300 mm
Process pressure: 0 bar ... 6 bar, gauge pressure
Process temperature: -25 °C ... 70 °C
1) At 6 bar gauge  
Performance
Resolution: 0.18 mm
Accuracy of sensor element: ≤ 2 % 1)
Repeatability: ± 0.15 % 2)
Response time: ≤ 180 ms 3)
1) 2) Of final value  3) Recovery time 32 ms ... 180 ms according to EMC EN 60947-5-7  
Mechanical data
Housing material: Stainless steel 1.4571, PBT, TPU
Process connection: G 1 A PN 6
 
Electrical data
Ultrasonic frequency: 180 kHz
Enclosure rating: IP 67
Supply voltage: 9 V DC ... 30 V DC 1)
Ripple: ± 10 %
Power consumption: ≤ 80 mA 2)
Time delay before availability: ≤ 300 ms
Output signal: 1 x PNP + 4 mA ... 20 mA / 0 V ... 10 V 3) 4)
Hysteresis: 20 mm
Signal voltage HIGH: Uv - 3 V
Connection type: Round connector M12 x 1, 5-pin
Ultrasonic transducer: PTFE coating, FFKM
1) Reverse-polarity protected  2) At 24 V DC without output load  3) Short-circuit protected, reversible  4) Automatic switching between voltage and current outputs dependet on load 4 mA ... 20 mA: RL = 100/ at 9 V = UB =20 V; RL = 500/ at UB = 20 V; 0 V … 10 V: RL =100 k/at UB = 15 V, short-circuit protected  
Ambient data
Ambient operating temperature: -25 °C ... 70 °C 1)
Ambient storage temperature: -40 °C ... 85 °C
1) Temperature compensation at -25 °C ... 50 °C, can be switched off  
Products specifications
Manufacturer category Sick UP
Manufacturer Sick